Steel-Lined PTFE Wound Lining Vessel
Classification:
Keywords:
Valve pipeline
Product details
Steel-lined PTFE wound lining vessels adopt PTFE films or strips, which are spirally wound onto the inner wall of steel components by special winding machines. After hot pressing and shaping, a seamless anti-corrosion lining layer is formed. Metal mesh is often embedded to enhance structural strength, pressure resistance and vibration resistance.
Product Features
① Suitable for high-pressure and highly corrosive media, with an operating temperature range of -60°C ~ 180°C, and instantaneous local temperature resistance up to 250°C;
② Resists negative pressure above -0.04 MPa; vacuum-resistant rings are required for pressure beyond this value;
③ Applicable to regular-shaped equipment with diameter Ø200~Ø2000.
Lining Thickness and Nominal Diameter Data for Nozzles of Steel Wound PTFE-lined Vessels (Unit: mm)
| Nominal diameter | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN125 | DN150 |
| Steel Pipe Selection Standards | Ø38×3 | Ø42×3 | Ø48×3 | Ø60×4 | Ø76×4 | Ø89×4 | Ø108×4 | Ø133×4 | Ø159×4.5 |
| Liner thickness | 4.5 | 4.5 | 4.5 | 5 | 5 | 5.5 | 6 | 6 | 7 |
| Liner diameter | 23 | 27 | 33 | 42 | 58 | 70 | 88 | 113 | 136 |
| Seal Face Thickness II | 2.8 | 2.8 | 3.1 | 3.1 | 3.4 | 3.4 | 3.4 | 4.2 | 4.6 |
| Nominal diameter | DN200 | DN250 | DN300 | DN350 | DN400 | DN450 | DN500 | DN600 | Subject |
| Steel Pipe Selection Standards | Ø219x6 | Ø273x7 | Ø325x8 | Ø377x9 | Ø426x9 | Ø480x10 | Ø530x10 | Ø630x10 | - |
| Liner thickness | 8 | 9 | 9 | 9 | 9 | 9 | 9 | 10 | 3~6 |
| Liner diameter | 191 | 241 | 291 | 341 | 390 | 442 | 492 | 590 | - |
| Seal Face Thickness II | 5.1 | 5.8 | 6.8 | 6.8 | 7.3 | 7.6 | 7.8 | 7.8 | 2~5 |
Standard for the selection of steel pipes for pressure vessels: GB/T 9948
Note:
1. Branch pipes shall be as short as possible in accordance with lining process requirements,
Recommended height above surface: 100~120mm for branch pipes and 200mm for manholes, excluding special conditions;
(Steel pipes for atmospheric pressure vessels comply with GB/T 8163, DN50~060x3)
2. The maximum nominal diameter of the main body is DN2000, and the lining thickness can be customized according to customer requirements.
Related products